Airflow and Indoor Air Quality Models of DOE Reference Commercial Buildings (Paperback)


Sixteen reference commercial buildings were defined by the U.S. Department of Energy (DOE) and created as EnergyPlus input files. They were developed for use in assessing new technologies and supporting the development of energy codes. Infiltration rates were inputs to the models, rather than calculated based on established building airflow theory. In order to support more physically-based airflow calculations, as well as contaminant transport analysis, models of the 16 reference buildings were created in the multizone airflow and contaminant program CONTAM. A number of key inputs had to be defined for the CONTAM models, including changes to the interior zoning to account for more realistic airflows. Annual airflow and contaminant simulations were performed in CONTAM for six of the buildings. As expected, the assumed infiltration rates in EnergyPlus did not realistically reflect impacts of indoor-outdoor weather conditions. In contrast, there were clear relationships between the air change rates calculated by CONTAM and weather. The infiltration rates assumed in EnergyPlus were also generally lower than those calculated by CONTAM. Contaminant analyses were also performed for occupant-generated carbon dioxide and volatile organic compounds from indoor sources, as well as for outdoor particulate matter and ozone.

R433

Or split into 4x interest-free payments of 25% on orders over R50
Learn more

Discovery Miles4330
Delivery AdviceShips in 10 - 15 working days


Toggle WishListAdd to wish list
Review this Item

Product Description

Sixteen reference commercial buildings were defined by the U.S. Department of Energy (DOE) and created as EnergyPlus input files. They were developed for use in assessing new technologies and supporting the development of energy codes. Infiltration rates were inputs to the models, rather than calculated based on established building airflow theory. In order to support more physically-based airflow calculations, as well as contaminant transport analysis, models of the 16 reference buildings were created in the multizone airflow and contaminant program CONTAM. A number of key inputs had to be defined for the CONTAM models, including changes to the interior zoning to account for more realistic airflows. Annual airflow and contaminant simulations were performed in CONTAM for six of the buildings. As expected, the assumed infiltration rates in EnergyPlus did not realistically reflect impacts of indoor-outdoor weather conditions. In contrast, there were clear relationships between the air change rates calculated by CONTAM and weather. The infiltration rates assumed in EnergyPlus were also generally lower than those calculated by CONTAM. Contaminant analyses were also performed for occupant-generated carbon dioxide and volatile organic compounds from indoor sources, as well as for outdoor particulate matter and ozone.

Customer Reviews

No reviews or ratings yet - be the first to create one!

Product Details

General

Imprint

Createspace Independent Publishing Platform

Country of origin

United States

Release date

March 2014

Availability

Expected to ship within 10 - 15 working days

First published

March 2014

Authors

Dimensions

280 x 216 x 9mm (L x W x T)

Format

Paperback - Trade

Pages

166

ISBN-13

978-1-4961-2845-4

Barcode

9781496128454

Categories

LSN

1-4961-2845-1



Trending On Loot